Eaton Tripp Lite Series PDU Switched ATS 120V 30A 24 5-15/20R; 1 L5-30R 2 L5-30P 2URM - Horizontal rackmount - power distribution unit (rack-mountable) - 30 A - AC 100/120/127 V - 2.9 kW - Ethernet - input: NEMA L5-30 - output connectors: 25 - 2U
Manufacturer: Eaton
Item Inso: 3232422
Sku: PDUMH30ATNET
Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Highly reliable solid-state switching between primary and secondary inputs occurs in 1-5 milliseconds. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability. Built-in LX Platform network management interface card. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
Product Description | Eaton Tripp Lite Series PDU Switched ATS 120V 30A 24 5-15/20R; 1 L5-30R 2 L5-30P 2URM - horizontal rackmount - power distribution unit - 2.9 kW |
Device Type | Power distribution unit - rack-mountable |
Rack Size | 2U |
Weight | 6.3 kg |
Input Voltage | AC 100/120/127 V |
Output Voltage | AC 120 V |
Power Capacity | 2.9 kW |
Input Connectors | 2 x power NEMA L5-30 |
Output connectors | 24 x power NEMA 5-15/20 ¦ 1 x power NEMA L5-30 |
Networking | Ethernet |
Remote Management Protocol | SNMP, HTTP |
Dimensions (WxDxH) | 44.5 cm x 31.8 cm x 8.8 cm |
Manufacturer Warranty | 2-year warranty |
Items included in the box :
ATS / Switched PDU with two L5-30P inputs |
Installable 2U mounting brackets |
Operating manual |