Eaton Tripp Lite Series PDU Switched ATS 120V 1.4kW 15A 5-15R 8 Outlet 2 5-15P 1URM


Description


Eaton Tripp Lite Series PDU Switched ATS 120V 1.4kW 15A 5-15R 8 Outlet 2 5-15P 1URM - Horizontal rackmount - power distribution unit (rack-mountable) - 15 A - AC 120 V - 1.4 kW - 1800 VA - Ethernet 10/100 - input: NEMA 5-15 - output connectors: 8 (NEMA 5-15/20) - 1U - black



Manufacturer: Tripp Lite
Item Inso: 406295
Sku: PDUMH15ATNET


Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. The built-in Java-free HTML5-based LX Platform interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, BOOTP and NTP. Switched PDU features include individually controllable output receptacles. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.


As this text is supplied by the manufacturer, we have no control over its language.

Product DescriptionEaton Tripp Lite Series PDU Switched ATS 120V 1.4kW 15A 5-15R 8 Outlet 2 5-15P 1URM - horizontal rackmount - power distribution unit - 1.4 kW - 1800 VA
Device TypePower distribution unit - rack-mountable
Rack Size1U
Weight5 kg
Input VoltageAC 120 V
Output VoltageAC 120 V
Power Capacity1.4 kW / 1800 VA
Input Connectors2 x power NEMA 5-15
Output connectors8 x power NEMA 5-15/20
NetworkingEthernet 10/100
Remote Management ProtocolSNMP, Telnet, HTTP
ColorBlack
Dimensions (WxDxH)44.4 cm x 36.8 cm x 4.4 cm
Manufacturer Warranty2-year warranty

Items included in the box :

ATS / Switched PDU with attached 5-15P input power cord
Detachable C13 to NEMA 5-15P 12 ft / 3.6m secondary input cord
Installable 1U mounting brackets
User manuals with warranty information

 